{"id":633,"date":"2024-08-05T14:27:33","date_gmt":"2024-08-05T12:27:33","guid":{"rendered":"https:\/\/megamultisite.divcomstaging.co.uk\/noff\/?page_id=633"},"modified":"2025-10-30T09:57:44","modified_gmt":"2025-10-30T09:57:44","slug":"shell-scheme-stand-information","status":"publish","type":"page","link":"https:\/\/divcommanual.com\/acuk\/shell-scheme-stand-information\/","title":{"rendered":"Shell Scheme Stand Information"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=&#8221;1\/1&#8243;][uncode_block id=&#8221;2247&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8221;121463&#8243;]<\/p>\n<p>Please\u00a0<a href=\"http:\/\/divcommanual.com\/acuk\/wp-content\/uploads\/sites\/18\/2025\/10\/Shell-Visual-For-Manual.pdf\" target=\"_blank\" rel=\"noopener\">click here<\/a> to see a SHELL SCHEME VISUAL.<\/p>\n<p>Please <a href=\"http:\/\/divcommanual.com\/acuk\/wp-content\/uploads\/sites\/18\/2025\/10\/GES-Shell-Brochure-Complete.pdf\" target=\"_blank\" rel=\"noopener\">click here<\/a> to download the SHELL SCHEME BROCHURE includes dimensions.<\/p>\n<p>The Standard Shell Scheme is built in the \u2018Complete\u2019 system and constructed by GES.<\/p>\n<p>Basic stands will consist of white walls, fascia, corner, mid-support posts, ceiling grid and grey carpet. The stand is constructed throughout in a silver aluminium system incorporating lightweight white panels 4mm thick.<\/p>\n<p>Infill wall panels are 4mm thick white foamex. All shell scheme stands have a name board with your company name and stand number applied directly to it. Fascia supports are provided at intervals not exceeding 3m apart. Large stands may require additional interior posts to support the grid.<\/p>\n<ul>\n<li><strong>Shell Scheme Heights:<\/strong><br \/>\nShell Height: 2.5m. The contract <u>does not include<\/u>\u00a0provision by the organisers of any of the following services:<\/p>\n<ul>\n<li>Connections for water, waste, gas or other utilities<\/li>\n<li>Interior fittings and displays<\/li>\n<li>Additional sign-writing<\/li>\n<li>Labour for off-loading<\/li>\n<li>Provision of night sheets<\/li>\n<li>Floral Decoration<\/li>\n<li>Communication lines (internet\/telephone)<\/li>\n<li>Electrical connections or lighting other than those included in the specified shell scheme \u2013 please refer to your sales contract.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Island shell scheme stands will not contain any walling and will be open on all four sides.<\/strong><\/li>\n<li><strong>Corner stands will either have two or three sides open, with walling on the other sides.<\/strong><\/li>\n<li><strong>Inline stands will have one open side onto the gangway, with walling on all other sides.\u00a0<\/strong><\/li>\n<li><strong>When ordering additional walling\/storage areas from the official contractor, you need to consider your neighbours. Stands incorporating long runs of gangway perimeter walling (more than 30% of any wall) will not be permitted if deemed by the organisers to have a detrimental effect on the show or surrounding stands<\/strong>.<\/li>\n<li><strong>Removal of fascia.<\/strong> If you wish to have your fascia removed please contact the organisers on <a href=\"mailto:pallsop@divcom.co.uk\" target=\"_blank\" rel=\"noopener\">pallsop@divcom.co.uk<\/a> and depending on where your stand is located and your neighbours build we may be able to remove the fascia but please be aware that this is not always possible.<\/li>\n<li><strong>Shell Scheme Extras. <\/strong>The official contractors offer a wide range of additional extras for shell scheme stands. Exhibitors are free to choose extras to enhance their stand if required. Full details and prices can be found in the Optional Orders section on the Shell Scheme Extra Form.<\/li>\n<li><strong>Carpet\/flooring. <\/strong>The floor covering throughout all shell scheme stand areas and gangways will be cord carpet. All shell scheme stands will have carpet provided (mid grey). The exhibitor will be responsible for any damage to the floor coverings, in or around the stand. Any damage caused to the carpet by an exhibitor or their contractor will be replaced, and the cost of replacement charged to the exhibitor.<\/li>\n<li><strong>Stand cleaning. <\/strong>Stands will be vacuumed prior to opening each morning FREE OF CHARGE. We recommend having a stock of refuse bags on your stand for waste. All sacks of waste should be left in the gangways after the show closes. Sacks left on stands will NOT be removed. All cardboard boxes should be flat packed for removal. PLEASE NOTE \u2013 the organisers do not supply bins or wastes sacks for your stand \u2013 you will need to ensure you have the appropriate provision for the activity taking place on your stand.\u00a0 The organisers would be grateful if stand holders would contact us, prior to the show, if they anticipate producing large amounts of rubbish i.e. cardboard boxes etc either before or during show open. This will help us open the show on time, as well as keep the show tidy during busy periods. Any waste left after breakdown that is deemed in excessive quantities will be recharged to the exhibitor for recycling\/removal costs. It is important where possible to re-use and recycle any waste you may produce on your stand during the show.<\/li>\n<li><strong>Electrics<\/strong>. Electrical work on your stand must be carried out by the appointed electrical stand contractor GES.<\/li>\n<\/ul>\n<p><strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Important Electrical Information &#8211;<\/strong><\/p>\n<ul>\n<li>Under no circumstances are exhibitors\u2019 own staff or any non-approved persons permitted to carry out electrical installation work within the venue<\/li>\n<li>Socket outlet multi-way adaptors are not permitted.<\/li>\n<li>Flexible cords must not exceed 2m in length.<\/li>\n<li>Appliances must have been tested by a qualified and competent person before connection to the power supply.<\/li>\n<li>All lighting shall be designed and installed to avoid nuisance and discomfort to neighbouring stands and to visitors. Lamps and appliances with high temperature surfaces installed below 2.5m must be totally enclosed in a non-combustible and non-conducting case and used well away from combustible materials.<\/li>\n<li>Flashing lights or signs are NOT permitted, but sequence displays may be used, subject to prior written approval by the organisers.<\/li>\n<li>No light fitting or other electrical appliance may be suspended from the roof of the hall. Lighting rigs are permitted \u2013 prior written authorisation from the organisers is required.<\/li>\n<li><strong>If 24-hour supply is required (for refrigeration, etc.) please contact the appointed electrical contractor GES<\/strong><\/li>\n<li>When ordering, always accompany your order with a drawing.<\/li>\n<li>Power to stands will be switched off <strong><u>30 MINUTES<\/u><\/strong> after the show closes every day. If you require power later than that on any of the show open days, please contact the electrical contractor through their Service Desk on site located at the front of the show. During build-up, power is not guaranteed until the last build-up day. If available before this time power will be turned on.<\/li>\n<li>Any prefabricated units already wired must comply in all respects with the safety regulations as deemed by the venue. The cost of any modification required to comply with these regulations will be charged to the exhibitor by the electrical contractor.<\/li>\n<li>A list of the most commonly requested electrical items, together with costs inclusive of the current consumed, will be found on electrical order form located in the Optional Orders section of the manual. Should you require any other electrical service, please contact the contractor GES directly &#8211; they will be pleased to assist you with any requirement you may have.<\/li>\n<li><strong>NB a surcharge of 20% will apply on all mains power ordered after the\u00a0<u>deadline detailed on the order form.<\/u><\/strong><\/li>\n<li><strong>A charge will also be levied for the movement of incorrectly placed electrical fittings.<\/strong><\/li>\n<\/ul>\n<p><strong>Nameboards.\u00a0<\/strong> Each shell scheme exhibitor will have their exhibiting name or company name lettered onto the name panel fascia on their stand in standard style capital letters. A name board will be fitted on the fascia of each open side of the shell scheme stand. Exhibitors are reminded that unless they complete their Show Guide Entry form their registered name or trade name only will be used.\u00a0<strong><u>NB: the company name displayed on the facia will be taken from your Show Guide entry.<\/u>\u00a0<\/strong>Please ensure that when completing the form any abbreviations are correct. Addresses will not be included. No display material or logos may be fixed to the fascia. If exhibitors wish to amend their name boards on site, a \u00a335 + VAT charge will apply for each new board.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/1&#8243;][uncode_block id=&#8221;2247&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text uncode_shortcode_id=&#8221;121463&#8243;] Please\u00a0click here to see a SHELL SCHEME VISUAL. Please click here to download the SHELL [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"class_list":["post-633","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/pages\/633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/comments?post=633"}],"version-history":[{"count":5,"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/pages\/633\/revisions"}],"predecessor-version":[{"id":6952,"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/pages\/633\/revisions\/6952"}],"wp:attachment":[{"href":"https:\/\/divcommanual.com\/acuk\/wp-json\/wp\/v2\/media?parent=633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}